Using a BERT for 100 Gb/s-per-lane receiver calibration and conformance testing
400G / 800G electrical receiver conformance testing requires the application of a stressed signal, simulating the worst-case scenario from a compliant transmitter and channel. The receiver must effectively equalize and capture the signal, ensuring a bit error ratio below specified limits. Complicating the process for 100 Gb/s link receivers are the lower noise thresholds of 56 Gbaud PAM4 signals and forward error correction (FEC), which require additional tuning and testing. IEEE 802.3ck and OIF-CEI-5.0 define conformance testing standards for 100 Gb/s receivers used in 400G and 800G Ethernet networks.
Electrical receiver conformance testing begins with precise calibration of the stressed signal and system. Performance validation includes interference tolerance and jitter tolerance tests, ensuring 400G / 800G receiver conformance for all possible deployment scenarios. Chip-to-module interface testing uses the stressed-eye method, with separate calibrations for host and module inputs. For chip-to-chip, backplane, or cable interfaces, the conformance test involves tuning the link channel operating margin by means of broadband noise injection. The test setup requires a bit error ratio tester (BERT) with PAM4 pattern generation and a high-bandwidth, low-noise oscilloscope to calibrate the receiver and stress signal.
400G / 800G electrical receiver conformance test solution
Conformance testing for 100 Gb/s receivers involves applying a stressed signal to simulate worst-case scenarios, requiring precise calibration and testing for interference and jitter tolerance. The Keysight 400G / 800G electrical receiver conformance test solution helps simplify physical layer conformance testing. It includes a 120 Gbaud BERT with high signal integrity performance and automated receiver test software. The software helps developers navigate complex compliance test requirements for the various links and automates testing to ensure repeatable, reliable results. The solution also includes a high-bandwidth, low noise Keysight Infiniium UXR-B Series oscilloscope and PAM4 analysis, jitter analysis, and signal integrity software to calibrate the receiver and FEC algorithm.
How to Test 400G / 800G Electrical Receiver Conformance
M8050A 120 Gbaud 고성능 BERT
키사이트 M8050A 고성능 비트 오류 비율 테스터(BERT)는 차세대 데이터 센터 네트워크 및 서버 인터페이스에 사용되는 수신기의 정확한 특성화를 지원합니다. 탁월한 신호 무결성과 함께 NRZ, PAM4, PAM6및 PAM8 신호와 최대 120 GBd의 데이터 전송 속도를 지원하는 M8050A의 유연한 아키텍처는 1.6T 패스파인딩을 비롯하여 기타 다양한 첨단 기술을 지원합니다.
How to Test 400G / 800G Electrical Receiver Conformance
M8091CKCA 수신기 적합성 테스트 어플리케이션(IEEE 802.3ck용)
M8091CKCA 전기 수신기 적합성 테스트 어플리케이션은 키사이트 디지털 통신 분석기(DCA) 오실로스코프와 함께 키사이트 M8040A 64Gbaud 고성능 BERT 또는 M8050A 120Gbd 고성능 BERT를 사용하여 IEEE 802.3ck Draft 3.3 칩-칩(C2C) 및 칩-모듈(C2M) 전기 인터페이스의 입력을 테스트하는 데 사용되는 스트레스 신호 교정을 지원하고 간소화할 수 있도록 설계되었습니다.